Extraction of DNA

DNA extraction (pages 77-78) was carried out on all the samples (samples A-B-C-D-E-F-G) using the automated extractor BioRobot “EZI” (Qiagen), as reported on page 78 of the RTIGF.

The Work Status Report (SAL) shows that:

  • the extraction of DNA from samples A-B-C was performed on 13.11.07;
  • the extraction of DNA from samples D-E-F-G was performed on 17.12.07.

The “Quantity of extract” was 50 μl for each sample (c.f. SAL).

 

Next: Quantification of DNA